home *** CD-ROM | disk | FTP | other *** search
/ Spec Disk 1998 Spring 4.0 / Spec Disk 1998 Spring 4.0.iso / generic / 07411bsc.gen < prev    next >
Text File  |  1998-06-10  |  8KB  |  159 lines

  1.     SECTION 07411
  2.  
  3.     GALVALUME(R) ROOF PANELS
  4. NOTE ** This section is based on preformed metal roofing that is manufactured from Galvalume(R) sheet, as produced by Bethlehem Steel Corporation, located at the following address:
  5. NOTE **     Bethlehem, Pennsylvania 18016-7699
  6. NOTE **     Tel. (800) 352-5700, extension 400.
  7. NOTE ** 
  8. NOTE ** Galvalume(R) sheet is a metallic coated sheet steel.  Its optimum 55% aluminum-zinc alloy coating provides exceptional long-term durability.  In addition, in combination with today's high performance paint systems, prepainted Galvalume(R) sheet provides this outstanding long-term performance with a wide range of aesthetic options.
  9. NOTE ** 
  10. NOTE ** Galvalume(R) is a registered trademark of BIEC International, Inc.
  11. NOTE ** 
  12. NOTE ** SECTION 07411 - GALVALUME ROOF PANELS, Copyright 1997, The Architect's Catalog, Inc.
  13.  
  14.  
  15. PART 1    GENERAL
  16.  
  17. 1.1    SECTION INCLUDES
  18. NOTE ** Edit items below as required for project.
  19.  
  20.     A.    Labor, materials, tools, equipment, and services for preformed Galvalume(R) roofing, including roof panels, flashings and all other accessories necessary for a sound, secure and complete installation.
  21.  
  22.     B.    Coordination with related work.
  23.  
  24. 1.2    RELATED SECTIONS
  25. NOTE ** Delete any sections below not relevant to this project; add others as required.
  26.  
  27.     A.    Section 05120 - Structural Steel.
  28.  
  29.     B.    Section 06100 - Rough Carpentry:  Framing and Sheathing.
  30.  
  31.     C.    Section 06150 - Wood Decking.
  32.  
  33.     D.    Section 07210 - Building Insulation.
  34.  
  35.     E.    Section 07620 - Sheet Metal Flashing and Trim.
  36.  
  37.     F.    Section 07900 - Joint Sealers.
  38.  
  39. 1.3    REFERENCES
  40. NOTE ** Add any references to the list below that are included in text you have added to the section.
  41.  
  42.     A.    ASTM A 792/A 792M - Standard Specification for Steel Sheet, 55% Aluminum-Zinc Alloy-Coated by the Hot-Dip Process, General Requirements.
  43.  
  44. 1.4    SUBMITTALS
  45.  
  46.     A.    Submit under provisions of Section 01300.
  47.  
  48.     B.    Product Data:  Submit manufacturer's product specifications, standard details, installation instructions and general recommendations, as applicable to materials and finishes for each component and for complete roofing installation.
  49.  
  50.     C.    Shop Drawings:  Submit complete shop drawings and erection details showing methods of erection, elevations and plans of roof panels, sections and details, anticipated loads, flashings and all other accessories, interfaces with all related work of other trades, and proposed identification of component parts and their finishes.
  51.  
  52.     D.    Selection Samples:  Submit color chips for selection of finishes.
  53.  
  54.     E.    Verification Samples:  Submit one sample of roof panel, including clips and battens if applicable.  Submit two color chip samples in color selected by Architect.
  55.  
  56.     F.    Certifications:  Submit certification that roofing assembly meets specified loading requirements and has been pretested to provide specified resistance to wind uplift, and air and water infiltration.
  57.  
  58. 1.5    QUALITY ASSURANCE
  59.  
  60.     A.    Manufacturer:  Minimum __ years experience in manufacturing roof panels similar to those required for this project.
  61.  
  62.     B.    Installer:  Minimum __ years experience in installing roof panels similar to those required for this project.
  63.  
  64.     C.    Field Measurements:  Where possible, take field measurements of structural framing and substrate to receive the roofing, prior to fabrication of roof panels.
  65.  
  66. 1.6    DELIVERY, STORAGE, AND HANDLING
  67.  
  68.     A.    Delivery:  Deliver roof panels to project site packaged to provide protection against transportation damage and adverse weather.  Inspect roof panels upon arrival at site.  Notify manufacturer of any damaged or stained material.
  69.  
  70.     B.    Storage:  Store all material and accessories above ground on well skidded platforms.  Elevate one end of each skid to allow for moisture run-off.  Store under waterproof covering.  Provide proper ventilation to prevent condensation build-up between each roof panel.
  71.  
  72.     C.    Handling:  Exercise extreme care in unloading, storing and erecting roof panels to prevent bending, warping, twisting, and surface damage.
  73.  
  74. 1.7    WARRANTY
  75.  
  76.     A.    Material Warranty:  Provide warranty issued by manufacturer to cover roof panel base metal against rupture, structural failure, or perforation due to exposure to normal atmospheric corrosion for a period of 20 years and 6 months.
  77. NOTE ** If warranty requirements below are retained, verify they are available from selected manufacturer.  Include required term of each warranty.
  78.  
  79.     B.    Weathertightness Warranty:  Provide warranty issued by installer to cover roofing against leaks arising out of or caused by ordinary wear and tear under normal weather and atmospheric conditions for a period of __ years.
  80.  
  81.     C.    Finish Warranty:  Provide manufacturer's warranty to cover roof panel finish against cracking, checking, blistering, peeling, flaking, chipping, chalking, and fading under normal atmospheric conditions for a period of __ years.
  82.  
  83.  
  84. PART 2    PRODUCTS
  85.  
  86. 2.1    MANUFACTURERS
  87.  
  88.     A.    Material:  Provide Galvalume(R) sheet as manufactured by Bethlehem Steel Corporation; Bethlehem PA 18016-7699; ASD. Tel. (800) 352-5700, extension 400.
  89. NOTE ** Contact Bethlehem for a current "Suppliers of Galvalume(R) Sheet Roofing Components"; Booklet #2879. 
  90.  
  91.     B.    Roofing:  Provide preformed Galvalume(R) roof panels, flashings and accessories from one of the following manufacturers:
  92.         1.    Manufacturer No. 1:  ____________________________.
  93.         2.    Manufacturer No. 2:  ____________________________.
  94.         3.    Manufacturer No. 3:  ____________________________.
  95.  
  96.     C.    Substitutions are not acceptable.
  97. NOTE ** Delete paragraph above or below;  edit as required for project.
  98.  
  99.     D.    Submit requests for substitutions in accordance with provisions of Section 01600.
  100.  
  101. 2.2    MATERIALS
  102.  
  103.     A.    Roof Panels, Flashings, and Accessories:  Structural quality aluminum-zinc alloy-coated steel sheet (Galvalume(R)), complying with ASTM A 792 and with coating weight, grade and thickness to suit manufacturer's standards.
  104. NOTE ** Retain paragraph below only if prefinished roofing is required.  Select paint system and color from manufacturer's standard offerings.
  105.  
  106.     B.    Finish:  Apply paint system by a pre-approved coil coater in accordance with Bethlehem's "Process Specification for Prepainted Galvalume(R) Sheet."
  107.         1.    Paint System:  ________________________________.
  108.         2.    Color:  ____________________________.
  109.         3.    Color:  As selected by Architect from manufacturer's standards.
  110.  
  111. 2.3    FABRICATION
  112.  
  113.     A.    Roll-form continuous roof panels, as detailed on approved shop drawings, in lengths up to manufacturer's maximum standard lengths.
  114.  
  115.     B.    Fabricate trim, flashing and accessories, as detailed on approved shop drawings.
  116.  
  117.     C.    Fabricate trim and flashing from same material as panel.
  118.  
  119.  
  120. PART 3    EXECUTION
  121.  
  122. 3.1    EXAMINATION
  123.  
  124.     A.    Verify that substrates and adjacent work are ready to receive work of this section.  Do not proceed until unsatisfactory conditions have been corrected.
  125.  
  126. 3.2    INSTALLATION
  127.  
  128.     A.    Install panels so they are weathertight, allowing for expansion and contraction.
  129.  
  130.     B.    Install panels in accordance with manufacturer's instructions and approved shop drawings.
  131.  
  132.     C.    Install panels plumb, level, and straight, with seams and ribs/battens parallel, conforming to the design as indicated.
  133.  
  134. 3.3    ADJUSTING AND CLEANING
  135.  
  136.     A.    Dispose of excess materials and remove debris from site.
  137.  
  138.     B.    Clean work in accordance with recommendations of roofing panel manufacturer.
  139.  
  140.     C.    Touch up minor scratches and abrasions with paint provided or approved by panel manufacturer.
  141.  
  142.     D.    Protect work against damage.  Replace any work that becomes damaged prior to final acceptance.
  143. NOTE ** DISCLAIMER:  The information presented in this document is for illustrative purposes only.  Bethlehem Steel Corporation assumes no responsibility for its use.  Anyone relying upon or making use of this information does so at his own risk and assumes any and all liability or other consequences resulting therefrom.
  144.  
  145.     END OF SECTION
  146. ??
  147.  
  148.  
  149.  
  150.  
  151.  
  152.  
  153.  
  154.  
  155.  
  156.     07411-1